MOVEMENT-SYSTEMS 2021.22
1 6 7 5 2 3 4 8 All dimensions in millimetres. Subject to changes. 253 Flap systems.Kinvaro.T-65 lift-up flap fitting ASSEMBLY AND INSTALLATION INSTRUCTIONS All dimensions in millimetres Required space Tipmatic Pin 2.2 155 185 107° KP KLS KOB 75° ø 10 min. 60 KB/2 KB/2 Side wall milling position 182.4 ±0.1 ±0.1 ±0.1 ±0.1 ±0.1 ±0.1 ±0.1 ±0.1 +0.2 0 min. 16 2.2 12.2 min. 4.7 170.2 2 3 152.5 FAO min. 14/max. 17 FAS min. 14/max. 17 137.3 37 96 ø5 R8 R8 ±0.1 148.15 177.5 30.2 147.7 129.9 15 Calculation of power factor (LF) Flap height (mm) x {flap weight (kg) + 2 x handle weight (kg)} Countersunk screw 3.5 x 13 mm CORNICE Flap thickness (KLS) Cabinet top panel (KOB) 16 18 19 20 22 24 19 57 64 67 70 77 84 Cornice (KP) FLAP WEIGHT Flap height (KLH) Power factor (LF) 250–550 500–1100 1000–2250 200 1.3–2.8 2.5–5.5 5.0–11.3 250 1.0–2.2 2.0–4.4 4.0–9.0 300 0.8–1.8 1.7–3.7 3.3–7.5 350 0.7–1.6 1.4–3.1 2.9–6.4 400 0.6–1.4 1.3–2.8 2.5–5.6 450 0.6–1.2 1.1–2.4 2.2–5.0 500 0.5–1.1 1.0–2.2 2.0–4.5 550 0.5–1.0 0.9–2.0 1.8–4.1 Flap weight in kg WARNING Important! Caution — risk of injury! Fitting is spring-tensioned! LEGEND FAO Front overlay, top FAS Front overlay, side KB Cabinet width KLS Flap thickness KOB Cabinet top panel KP Cornice LF Power factor Flap systems Kinvaro